CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the system, and protecting against electrostatic discharge.

NOTE: If your system fails to boot, press the System ID button for at least five seconds until an error code appears on the LCD. Record the code, then see "Getting Help" on page 205.

Table 1-5. LCD Status Messages

Code

Text

Causes

Corrective Actions

 

 

 

 

N/A

SYSTEM NAME

A 62-character string that

This message is for

 

 

can be defined by the user in

information only.

 

 

the System Setup program.

You can change the

 

 

The SYSTEM NAME

system ID and name in

 

 

displays under the following

the System Setup

 

 

conditions:

program (see "Entering

 

 

• The system is powered on. the System Setup

 

 

• The power is off and

Program" on page 43).

 

 

 

 

 

active errors are displayed.

 

E1000

FAILSAFE,

Check the system event log

See "Getting Help" on

 

Call Support

for critical failure events.

page 205.

E1114

Temp Ambient

Ambient system

See "Troubleshooting

 

 

temperature is out of

System Cooling

 

 

acceptable range.

Problems" on page 172.

E1118 CPU Temp

The BMC is unable to

Interface

determine the processor(s)

 

temperature status.

 

Consequently, the BMC

 

increases the processor fan

 

speed to maximum

 

as a precautionary measure.

Turn off power to the system and restart the system. If the problem persists, see "Getting Help" on page 205.

E1210 CMOS Batt

CMOS battery is missing, or

See "Troubleshooting the

 

the voltage is out of

System Battery" on

 

acceptable range.

page 170.

About Your System

19

Page 19
Image 19