Table 1-5. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1414

CPU #

Specified microprocessor is

See "Troubleshooting

 

Thermtrip

out of acceptable

System Cooling

 

 

temperature range and has

Problems" on page 172. If

 

 

halted operation.

the problem persists,

 

 

 

ensure that the

 

 

 

microprocessor heat sinks

 

 

 

are properly installed (see

 

 

 

"Troubleshooting the

 

 

 

Microprocessors" on

 

 

 

page 189).

 

 

 

NOTE: The LCD continues

 

 

 

to display this message

 

 

 

until the system’s power

 

 

 

cable is disconnected and

 

 

 

reconnected to the AC

 

 

 

power source, or the SEL is

 

 

 

cleared using either Server

 

 

 

Assistant or the BMC

 

 

 

Management Utility. See

 

 

 

the Dell OpenManage™

 

 

 

Baseboard Management

 

 

 

Controller User’s Guide for

 

 

 

information about these

 

 

 

utilities.

E1418

CPU #

Specified processor is

See "Troubleshooting the

 

Presence

missing or bad, and the

Microprocessors" on

 

 

system is in an unsupported

page 189.

 

 

configuration.

 

E141C

CPU Mismatch

Processors are in a

Ensure that your

 

 

configuration unsupported

processors match and

 

 

by Dell.

conform to the type

 

 

 

described in the

 

 

 

Microprocessor Technical

Specifications outlined in your system’s Getting Started Guide.

About Your System

23

Page 23
Image 23
Dell T605, DR715 owner manual E1414, Thermtrip, E1418, Presence, E141C CPU Mismatch