Table 1-5. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1A15

SAS Cable D

SAS cable D is missing or

Reseat the cable. If the

 

 

bad.

problem persists, replace

 

 

 

cable.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 205.

E1A18

PDB Ctrl

Control cable for the power

Reseat the cable. If the

 

Cable

distribution board (PDB) is

problem persists, replace

 

 

missing or bad.

cable.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 205.

E1A19

12V Cable

Power cable for the PDB or

Reseat the cable. If the

 

Fault

cabled power supply is

problem persists, replace

 

 

missing or bad. They system

cable.

 

 

will not turn on.

If the problem persists,

 

 

 

see "Getting Help" on page 205.

E1B01 USB#

Device plugged in the

Overcurrent

specified USB port caused

 

an overcurrent condition.

Reseat the device cable. If the problem persists, replace or remove the device.

E2010 No Memory

No memory is installed in

 

the system.

Install memory (see "Installing Memory Modules" on page 130).

E2011

Mem Config

Memory detected, but is not

See "Troubleshooting

 

Err

configurable. Error detected

System Memory" on

 

 

during memory

page 174.

 

 

configuration.

 

E2012

Unusable

Memory is configured, but

See "Troubleshooting

 

Memory

not usable. Memory

System Memory" on

 

 

subsystem failure.

page 174.

28

About Your System

Page 28
Image 28
Dell DR715, T605 E1A15 SAS Cable D, E1A18 PDB Ctrl, E1A19 12V Cable, Fault, E1B01 USB#, Overcurrent, E2010 No Memory, Err