Table 1-5. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1811

HDD ## Rbld

The specified hard drive has

See "Troubleshooting a

 

Abrt

experienced a rebuild abort.

Hard Drive" on page 181.

 

 

 

If the problem persists,

 

 

 

see your RAID

 

 

 

documentation.

E1812

HDD ##

The specified hard drive has

Information only.

 

Removed

been removed from the

 

 

 

system.

 

E1914 DRAC5 Conn2

DRAC 5 cable is missing or

Cbl

disconnected.

Reconnect the cable (see "Installing a RAC Card" on page 119).

E1915 IO55 HTSink

Heat sink sensor reports that

See "Getting Help" on

Missing

the chipset IO55 heat sink is

page 205.

MCP55 Htsink

missing.

 

Missing

Heat sink sensor reports that

 

 

the chipset MCP heat sink is

 

 

missing.

 

E1A14 SAS Cable A SAS cable A is missing or bad.

E1A15 SAS Cable B SAS cable B is missing or bad.

E1A15 SAS Cable C SAS cable C is missing or bad.

Reseat the cable. If the problem persists, replace cable.

If the problem persists, see "Getting Help" on page 205.

Reseat the cable. If the problem persists, replace cable.

If the problem persists, see "Getting Help" on page 205.

Reseat the cable. If the problem persists, replace cable.

If the problem persists, see "Getting Help" on page 205.

About Your System

27

Page 27
Image 27
Dell T605 E1811 HDD ## Rbld, Abrt, E1812 HDD ##, Removed, E1914 DRAC5 Conn2, Cbl, E1915 IO55 HTSink, Missing, MCP55 Htsink