Table 1-6. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

PCIe Fatal Error

PCI Express fatal errors

Reseat the PCIe card in the

caused a system

occurred during the previous

specified slot number (see

reset: Slot X

boot.

"Installing an Expansion

Embedded

 

Card" on page 110). If the

 

problem persists, see

Bus#XX/Dev#XX/Fu

 

 

"Getting Help" on page 205.

ncX

 

 

 

Please check the

 

 

system event log

 

 

for details

 

 

Plug & Play

Error encountered in

Install the NVRAM_CLR

Configuration

initializing PCIe device;

jumper and restart the

Error

faulty system board.

system. See Figure 6-1 for

 

 

jumper location. If the

 

 

problem persists, see

 

 

"Troubleshooting Expansion

 

 

Cards" on page 187.

Read fault

Requested sector not found

Remote configuration update attempt failed

The operating system cannot read from the hard drive or USB device, the system could not find a particular sector on the disk, or the requested sector is defective.

System unable to process Remote Configuration request.

Replace the USB medium or device. Ensure that the USB or hard drive cables are properly connected. See "Troubleshooting a USB Device" on page 165, or "Troubleshooting a Hard Drive" on page 181 for the appropriate drive(s) installed in your system.

Retry Remote Configuration.

About Your System

37

Page 37
Image 37
Dell T605, DR715 owner manual PCIe Fatal Error, Caused a system, Reset Slot, Embedded, Bus#XX/Dev#XX/Fu