Installing a Non-redundant Power Supply

1If you are installing a non-redundantpower supply to replace redundant power supplies, you will need to replace the power supply distribution board with the power supply cage cover.

a Remove the power supply distribution board. See "Removing the Power Supply Distribution Board" on page 143.

b Install the power supply cage cover by pressing the cover into the power supply cage until the retention pins lock into place. See Figure 3-41.

2Slide the power supply into the back of the system until the power supply release tab snaps into place. See Figure 3-8.

3Install the two Phillips screws to secure the power supply to the system. See Figure 3-8.

4Depending on your system configuration, connect the following power cables:

PWR1 connector on the system board

PWR2 connector on the system board

PWR3 connector on the system board

BP_PWR connector on the optional SAS/SATA backplane

Hard drives

Diskette drive

Tape backup unit

Optical drives

5Install the processor shroud. See "Installing the Processor Shroud" on page 74.

6Install the expansion card shroud. See "Installing the Expansion Card Shroud" on page 75.

7Close the system. See "Closing the System" on page 70.

8Place the system upright and on its feet on a flat, stable surface.

9Reattach any peripherals, then connect the system to the electrical outlet.

10Turn on the system and attached peripherals.