Table 1-5. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E201F

DRAC Config

Dell remote access

Check screen for specific

 

 

controller (DRAC)

error messages.

 

 

configuration failure.

Ensure that DRAC cables

 

 

 

 

 

 

and connectors are

 

 

 

properly seated. If

 

 

 

problem persists, see your

 

 

 

DRAC documentation.

E2020

CPU Config

Processor configuration

Check screen for specific

 

 

failure.

error messages.

E2021

Memory

Incorrect memory

Check screen for specific

 

Population

configuration. Memory

error messages (see

 

 

population order incorrect.

"Troubleshooting System

 

 

 

Memory" on page 174).

E2022

POST Fail

General failure after video.

Check screen for specific

 

 

 

error messages.

E2110

MBE DIMM # &

One of the DIMMs in the

See "Troubleshooting

 

#

set implicated by "# & #"

System Memory" on

 

 

has had a memory multi-bit

page 174.

 

 

error (MBE).

 

E2111

SBE Log

The system BIOS has

See "Troubleshooting

 

Disable DIMM

disabled memory single-bit

System Memory" on

 

#

error (SBE) logging, and will

page 174.

 

 

not resume logging further

 

 

 

SBEs until the system is

 

 

 

restarted. "#" represents the

 

 

 

DIMM implicated by the

 

 

 

BIOS.

 

E2112

Mem Spare

The system BIOS has spared

See "Troubleshooting

 

DIMM #

the memory because it has

System Memory" on

 

 

determined that the

page 174.

 

 

memory had too many

 

 

 

errors. "# & #" represents

 

 

 

the DIMM pair implicated

 

 

 

by the BIOS.

 

30

About Your System

Page 30
Image 30
Dell DR715, T605 E201F Drac Config, E2020 CPU Config, E2021 Memory, Population, E2022 Post Fail, E2110, E2111 SBE Log