Dell DR715 More than one RAC, Detected, system, Halted, No boot device, Available, No timer tick

Models: T605 DR715

1 230
Download 230 pages 2.18 Kb
Page 36
Image 36

Table 1-6. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

More than one RAC

More than one RAC card has

Remove additional RAC

detected, system

been detected.

card(s). You may only have a

halted

 

maximum of one RAC card

 

 

installed (see "Installing a

 

 

RAC Card" on page 106).

No boot device

Faulty or missing optical

available

drive subsystem, hard drive,

 

or hard-drive subsystem, or

 

no bootable USB key

 

installed.

Use a bootable USB key, CD, or hard drive. If the problem persists, see "Troubleshooting an Internal USB Key" on page 176 and "Troubleshooting a Hard Drive" on page 181. See "Entering the System Setup Program" on page 43 for information on setting the order of boot devices.

No boot sector on Incorrect configuration

hard drive settings in System Setup program, or no operating system on hard drive.

Check the hard-drive configuration settings in the System Setup program (see "Entering the System Setup Program" on page 43). If necessary, install the operating system on your hard drive (see your operating system documentation).

No timer tick

Faulty system board.

interrupt

 

PCI BIOS failed

PCIe device BIOS (Option

to install

ROM) checksum failure

 

detected during shadowing.

 

Cables to expansion card(s)

 

loose; faulty or improperly

 

installed expansion card(s).

See "Getting Help" on page 205."

Reseat the expansion card(s). Ensure that all appropriate cables are securely connected to the expansion card(s). If the problem persists, see "Troubleshooting Expansion Cards" on page 187.