Table 1-5. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1211

ROMB Batt

RAID battery is either

Reseat the RAID battery

 

 

missing, bad, or unable to

connector (see "Installing

 

 

recharge due to thermal

a RAID Battery" on

 

 

issues.

page 115, and

 

 

 

"Troubleshooting System

 

 

 

Cooling Problems" on

 

 

 

page 172).

E1214

## PwrGd

Specified voltage regulator

See "Getting Help" on

E1216

 

has failed.

page 205.

 

 

 

E1217

 

 

 

E121A

8V PwrGd

8V voltage regulator has

Recycle power to the

 

 

failed.

system or clear the SEL. If

 

 

 

the problem persists, see

 

 

 

"Getting Help" on

 

 

 

page 205.

E121D 1.2V VM Dual

1.2V voltage regulator for

PwrGd

the VM dual signal has

 

failed.

Recycle power to the system or clear the SEL. If the problem persists, see "Getting Help" on

page 205.

E1227

Linear PwrGd

Linear voltage regulator(s)

See "Getting Help" on

 

 

has failed. Represents status

page 205.

 

 

of multiple voltage

 

 

 

regulators used in the video

 

 

 

and LOM circuitry.

 

E1229

CPU # VCORE

Processor # VCORE voltage

See "Getting Help" on

 

 

regulator has failed.

page 205.

E122A CPU VTT PwrGd

E122D CPU # VDDIO 1.0V PwrGd

Processor # VTT voltage has

See "Getting Help" on

exceeded the allowable

page 205.

voltage range.

 

Processor # VDDIO voltage

See "Getting Help" on

has exceeded the allowable

page 205.

voltage range.

 

20

About Your System

Page 20
Image 20
Dell DR715 E1211 Romb Batt, E1214 ## PwrGd, E1216, E1217 E121A 8V PwrGd, E121D 1.2V VM Dual, E1227 Linear PwrGd, E1229