Delta DOP Series HMI Connection ManualDOP-A/AE/AS Series
AllenBradley MicroLogix PLCBack to Table A. HMI factory setting
Baud rate: 19200, 8, None, 1.
PLC station number: 1.
Control area/status area: B3:0/B3:10.
B. Definition of controller Read/Write address
Registers
|
|
| Read/Write Range | |||
Register Type | Format | Word No. |
|
| Bit No. | |
| Low Byte |
| High Byte | |||
|
|
|
| |||
|
|
|
|
| File No. | |
|
|
|
|
|
| |
Output File | O:n | n: 0 ~ 3 |
| N/A |
| 0 |
|
|
|
|
|
|
|
Input File | I:n | n: 0 ~ 3 |
| N/A |
| 1 |
|
|
|
|
|
|
|
Status File | S2:n | n: 0 ~ 65 |
| N/A |
| 2 |
|
|
|
|
|
|
|
Bit File | B3:n | n: 0 ~ 255 |
| N/A |
| 3 |
|
|
|
|
|
|
|
Timer Flag | T4:n | n: 0 ~ 255 |
| N/A |
| 4 |
|
|
|
|
|
|
|
Timer Preset Value | T4:n.PRE | n: 0 ~ 255 |
| N/A |
| 4 |
|
|
|
|
|
|
|
Timer Accumulator Value | T4:n.ACC | n: 0 ~ 255 |
| N/A |
| 4 |
|
|
|
|
|
|
|
Counter Flag | C5:n | n: 0 ~ 255 |
| N/A |
| 5 |
|
|
|
|
|
|
|
Counter Preset Value | C5:n.PRE | n: 0 ~ 255 |
| N/A |
| 5 |
|
|
|
|
|
|
|
Counter Accumulator Value | C5:n.ACC | n: 0 ~ 255 |
| N/A |
| 5 |
|
|
|
|
|
|
|
Control File | R6:n | n: 0 ~ 255 |
| N/A |
| 6 |
|
|
|
|
|
|
|
Control Size of Bit Array | R6:n.LEN | n: 0 ~ 255 |
| N/A |
| 6 |
|
|
|
|
|
|
|
Control Reserved File | R6:n.POS | n: 0 ~ 255 |
| N/A |
| 6 |
|
|
|
|
|
|
|
Integer File | N7:n | n: 0 ~ 255 |
| N/A |
| 7 |
|
|
|
|
|
|
|
¾Bit No : Low byte is not used, so the value is 0. High byte stores file number.
¾Data Size : Word.
¾T4, C5 and R6 only read 1 Word once.
¾If reading multiple Words once, the communication speed of PLC will be slow.
NOTE
1)After last communication data has been memorized by PLC (PLC will send 0x10 0x05 consecutively), communication may fail. At this time, power off and power up HMI or power off and power up PLC once.
Revision January, 2008, Doc. Name: 2007PDD23000007 |