Delta DOP Series HMI Connection ManualDOP-A/AE/AS Series

Mitsubishi FX Series PLC via Computer Link

Back to Table

A. HMI factory settings

Baud rate: 9600, 7, EVEN, 1.

Controller Station number: 0.

Control area/status area: D0 / D10.

NOTE

1)This communication protocol supports FX series RS485 and RS232 communication module.

2)The default setting of this communication protocol is to support RS485 communication module. If the user needs to use RS232 communication module, the user must change the communication setting from RS485 to RS232 manually.

3)For more detailed information regarding the communication setting method, please refer to Mitsubishi Communication User Manual named “User’s Manual - Data Communication Edition”.

B. Definition of controller Read/Write address

Registers

Register Type

Format

Read/Write Range

Data length

Word No.

Bit No.

 

 

 

Auxiliary Relay

Mn

n: 0-7679

N/A

Word

 

 

 

 

 

Special Auxiliary Relay

Mn

n: 8000-8511

N/A

Word

 

 

 

 

 

Status Relay

Sn

n: 0-4095

N/A

Word

 

 

 

 

 

Input Relay

Xn

n: 0-377(octal)

N/A

Word

 

 

 

 

 

Output Relay

Yn

n: 0-377(octal)

N/A

Word

 

 

 

 

 

Timer PV

Tn

n: 0-255

N/A

Word

 

 

 

 

 

16-bit Counter PV

Cn

n: 0-199

N/A

Word

 

 

 

 

 

32-bit Counter PV

Cn

n: 200-255

N/A

Double Word

 

 

 

 

 

Data Register

Dn

n: 0-7999

N/A

Word

 

 

 

 

 

Special Data Register

Dn

n: 8000-8511

N/A

Word

 

 

 

 

 

¾Auxiliary Relay / Special Auxiliary Relay / Status Relay / Input Relay / Output Relay: Address must be the multiple of 16.

Contacts

Contact type

 

Format

 

Read/Write Range

 

 

Word No.

 

Bit No.

 

 

 

 

 

 

Auxiliary Relay

Mn

 

N/A

 

n: 0-7679

 

 

 

 

 

 

 

 

Special Auxiliary Relay

Mn

 

N/A

 

n: 8000-8511

 

 

 

 

 

 

 

 

Status Relay

Sn

 

N/A

 

n: 0-4095

 

 

 

 

 

 

 

1-86

 

 

Revision January, 2008, Doc. Name: 2007PDD23000007

Page 87