(C15, C16, C17). If the data length is out of this range, i.e. occupy other addresses except C0~C17, an error may occur.

6)The effective addresses of Cn are not consecutive (5 blocks: C0~17, C40~41, C45~C48, C50, C90~C92). However, when executing duplicate function (Decrease Address), the addresses will be regarded as consecutive addresses. For example, the next address of C90 is C50; the next address of C50 is C48; the next address of C45 is C41; the next address of C40 is C17.

7)When all Word address is written, the controllers all response ACK(0x06). But when all Word address is read, the receive value will not change. The user needs to press ACT_DATA0 again and then the receive value will be updated.

1-92

Revision January, 2008, Doc. Name: 2007PDD23000007

Page 93
Image 93
Delta Electronics manual Delta DOP Series HMI Connection ManualDOP-A/AE/AS Series