Delta DOP Series HMI Connection ManualDOP-A/AE/AS Series
Modbus nW (Master) | Back to Table |
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1. (ASCII)
9600, 8, EVEN, 1. (RTU)
Controller station number: 1.
Control area/status area: W40100 / W40200.
NOTE
1)This driver can read consecutive communication address on the screen via one Modbus command to improve the communication efficiency. For example, if there are 6 devices on the screen, and read the data of the addresses W40100, W40101, W40102, W40200, W40201, W40300. It will read three times. It will read W40100 3 Words at the first time, read W40200 2 Words at the second time and read W40300 1 Word at the third time.
2)Ensure to check the box next to “Optimize” (Optimization for reading) selection in “Communication” tab in the “Configuration” dialog box in “Options” menu (Options Æ Configuration Æ Communication). If “Optimize” selection is unchecked, do not select “Data Length Limit”.
B.Definition of controller Read/Write address
Registers
Register Type |
| Format | Read/Write Range | Data length | ||
| Word No. |
| Bit No. | |||
|
|
|
|
| ||
Output Registers | Wn |
| n: 40001 ~ 50000 | N/A |
| Word |
|
|
|
|
|
|
|
Input Registers | Wn |
| n: 30001 ~ 40000 | N/A |
| Word |
|
|
|
|
|
|
|
¾Input Registers is “read only”.
Contacts
Contact type |
| Format |
| Read/Write Range | |
| Word No. |
| Bit No. | ||
|
|
|
| ||
Discrete Outputs | Bn |
| N/A |
| n: 1 ~ 10000 |
|
|
|
|
|
|
Discrete Inputs | Bn |
| N/A |
| n: 10001 ~ 20000 |
|
|
|
|
|
|
¾Discrete Inputs is “read only”.
C. Connections (Connector Pinouts)
Please refer to 1.1 Pin Definition of Serial Communication for detail.
Revision January, 2008, Doc. Name: 2007PDD23000007 |