Delta DOP Series HMI Connection ManualDOP-A/AE/AS Series
¾WORD_DEVICE_I / WORD_DEVICE_E / WORD_DEVICE_L / WORD_DEVICE_M: Address must be 1 or the multiple of 16+1.
¾WORD_DEVICE_X / WORD_DEVICE_Y / WORD_DEVICE_L / WORD_DEVICE_W: Valid address is inconsecutive.
Contacts
Contact type | Format |
|
| Bit No. |
BIT_DEVICE_X | Xn | n: 201 ~ 65464 | ||
BIT_DEVICE_Y | Yn | n: 201 ~ 65464 | ||
BIT_DEVICE_I | In | n: 1 ~ | 16384 | |
BIT_DEVICE_E | En | n: 1 | ~ | 4096 |
BIT_DEVICE_L | Ln | n: 1 | ~ | 65488 |
BIT_DEVICE_M | Mn | n: 1 | ~ | 9984 |
BIT_DEVICE_TU | TUn | n: 1 ~ | 3072 | |
|
|
|
|
|
BIT_DEVICE_CU | CUn | n: 1 | ~ | 3072 |
|
|
|
|
|
¾BIT_DEVICE_X / BIT_DEVICE_Y : the last two digits of address must be less than 65 (1 ~ 64).
¾BIT_DEVICE_X / BIT _DEVICE_Y / BIT _DEVICE_L : valid address is inconsecutive.
¾Multiple Duplicate:
The next Bit address of X264 is X301 (invalid addresses X265 ~ X300 are skipped) The next Bit address of X364 is X401.
The address of Y is the same as X.
(The Word addresses of X and Y also skip invalid addresses automatically)
C.Connections (Connector Pinouts)
It needs to use specific cable of YOKOGAWA ACE PLC.
RS-232
DOP | Controller (6 pin) | Controller (6 pin) |
9 pin | YOKOGAWA) |
RXD (2) |
|
|
| (1) TXD |
|
|
| ||
TXD (3) |
|
| (2) RXD | |
|
| |||
GND (5) |
|
| (5) GND | |
| ||||
|
|
|
| Top View |
Revision January, 2008, Doc. Name: 2007PDD23000007 |