Delta DOP Series HMI Connection ManualDOP-A/AE/AS Series
Mitsubishi J2s Series ServoBack to Table A. HMI factory settings
Baud rate: 9600, 8, Even, 1
Controller Station number: 0.
Control area/status area: None / None.
B. Definition of controller Read/Write address
Registers
Register Type | Format | Read/Write Range | Data length |
| |
Word No. | Bit No. |
| |||
|
|
|
| ||
Parameter List | Pn | n: 0 – 84 | N/A | Double word |
|
(cmd: 05/84) (NOTE 1) |
| ||||
Status Display | Sn | n: 0 – E | N/A | Double word |
|
(cmd: 01,8n/NA) (NOTE 1) |
| ||||
Alarm Number in history | ANn | n: 0 – 5 | N/A | Word |
|
(cmd: 33,1n/NA) (NOTE 1) |
| ||||
Alarm Occurrence time in history (AO) | AOn | n: 0 – 5 | N/A | Double word |
|
(cmd: 33,2n/NA) (NOTE 1) |
| ||||
Current Alarm Number (AC) | ACn | n: 0 | N/A | Word |
|
(cmd: 02/NA) (NOTE 1) |
| ||||
Status Display at alarm occurrence (AS) | ASn | n: 0 | N/A | Double word |
|
(cmd: 35,8/NA) (NOTE 1) |
| ||||
External input pin status (EI) | EIn | n: 0 | N/A | Double word |
|
(cmd: 12,40/92,00) (NOTE 1) |
| ||||
External output pin status (EO) | EOn | n: 0 | N/A | Double word |
|
(cmd: 12,C0/92,A0) (NOTE 1) |
| ||||
Operation mode selection (OP) | OPn | n: 0 | N/A | Word |
|
(cmd: NA/8B,00) (NOTE 1) |
| ||||
Speed for test operation (TSPD) | TSPDn | n: 0 | N/A | Word |
|
(cmd: NA/A0,10) (NOTE 1) |
| ||||
Acceleration/deceleration for test | TACCn | n: 0 | N/A | Double word |
|
operation (TACC) |
| ||||
(cmd: NA/A0,11) (NOTE 1) |
|
|
|
|
|
Distance for test operation (TDIS) | TDISn | n: 0 | N/A | Double word |
|
(cmd: NA/A0,13) (NOTE 1) |
| ||||
Contacts |
|
|
|
|
|
|
|
|
| ||
Contact type |
| Format | Read/Write Range | ||
| Word No. | Bit No. | |||
|
|
| |||
Status display clear (SRST) |
| SRSTb | N/A | b: 0 | |
(cmd: NA/81,00) (NOTE 1) |
| ||||
Alarm history clear (ACLR) |
| ACLRb | N/A | b: 0 | |
(cmd: NA/82,20) (NOTE 1) |
| ||||
| Revision January, 2008, Doc. Name: 2007PDD23000007 |