Delta DOP Series HMI Connection ManualDOP-A/AE/AS Series

Contacts

 

 

 

Read/Write Range

Contact Type

Format

Word No.

 

 

Bit No.

 

Low Byte

 

High Byte

 

 

 

 

 

 

 

 

Bits

 

File No.

Output

O:n/b

n: 0 ~ 3

 

b: 0 ~ 15

 

0

 

 

 

 

 

 

 

Input

I:n/b

n: 0 ~ 3

 

b: 0 ~ 15

 

1

 

 

 

 

 

 

 

Status

S2:n/b

n: 0 ~ 65

 

b: 0 ~ 15

 

2

 

 

 

 

 

 

 

Bit

B3:n/b

n: 0 ~ 255

 

b: 0 ~ 15

 

3

 

 

 

 

 

 

 

Timer

T4:n/b

n: 0 ~ 255

 

b: 0 ~ 15

 

4

 

T4:n/EN

n: 0 ~ 255

 

15

 

 

 

T4:n/TT

n: 0 ~ 255

 

14

 

 

 

T4:n/DN

n: 0 ~ 255

 

13

 

 

 

 

 

 

 

 

 

Timer Preset Value

T4:n.PRE/b

n: 0 ~ 255

 

b: 0 ~ 15

 

4

 

 

 

 

 

 

 

Timer Accumulator Value

T4:n.ACC/b

n: 0 ~ 255

 

b: 0 ~ 15

 

4

 

 

 

 

 

 

 

Counter flag

C5:n/b

n: 0 ~ 255

 

b: 0 ~ 15

 

5

 

C5:n/CU

n: 0 ~ 255

 

15

 

 

 

C5:n/CD

n: 0 ~ 255

 

14

 

 

 

C5:n/DN

n: 0 ~ 255

 

13

 

 

 

C5:n/OV

n: 0 ~ 255

 

12

 

 

 

C5:n/UN

n: 0 ~ 255

 

11

 

 

 

C5:n/UA

n: 0 ~ 255

 

10

 

 

 

 

 

 

 

 

 

Counter Preset Value

C5:n.PRE/b

n: 0 ~ 255

 

b: 0 ~ 15

 

5

 

 

 

 

 

 

 

Counter Accumulator Value

C5:n.ACC/b

n: 0 ~ 255

 

b: 0 ~ 15

 

5

 

 

 

 

 

 

 

Control

R6:n/b

n: 0 ~ 255

 

b: 0 ~ 15

 

6

 

R6:n/EN

n: 0 ~ 255

 

15

 

 

 

R6:n/DN

n: 0 ~ 255

 

13

 

 

 

R6:n/ER

n: 0 ~ 255

 

11

 

 

 

R6:n/UL

n: 0 ~ 255

 

10

 

 

 

R6:n/IN

n: 0 ~ 255

 

9

 

 

 

R6:n/FD

n: 0 ~ 255

 

8

 

 

 

 

 

 

 

 

 

Control Size of Bit Array

R6:n.LEN/b

n: 0 ~ 255

 

b: 0 ~ 15

 

6

 

 

 

 

 

 

 

Control Reserved

R6:n.POS/b

n: 0 ~ 255

 

b: 0 ~ 15

 

6

 

 

 

 

 

 

 

Integer

N7:n/b

n: 0 ~ 255

 

b: 0 ~ 15

 

7

 

 

 

 

 

 

 

¾Bit No : Low byte stores Bit address. High byte stores file number.

Revision January, 2008, Doc. Name: 2007PDD23000007

1-15

Page 16
Image 16
Delta Electronics DOP-A/AE/AS manual Contacts