Dynalink RTA1046VW user manual 136, Mode, System Log Configuration

Models: RTA1046VW

1 172
Download 172 pages 50.51 Kb
Page 150
Image 150

Wireless IAD User Manual

Therefore, when the log level is “Debugging” and the display level is “Error”, the CPE logs the most detailed message but shows error level data only.

Mode:

You can choose where to store the logs; the options include Local, Remote and Both. Local means the CPE, i.e., the wireless IAD. Remote means the log server you specified to forward the log information to. The default mode is Local.

If you choose Remote or Both, you have to specify the Server IP Address and UDP Port, and all the events will be sent to the specified UDP port of the specified log server.

Note:

Display Level only filters for the local side. All the messages will be displayed on the remote Log Server.

Example

Suppose we are going to record the system logs on both the wireless IAD and the Server bearing IP address 10.11.95.2, the procedures below illustrate the situation:

System Log Configuration

1.Choose Enabled Log.

2.Select Debugging as the Log Level, and Error as the Display Level. (Or select other level according to your needs.)

3.Set the Mode as Both, key in the Server IP Address as 10.11.95.2, and leave the Server UDP Port as the default value 514.

4.Press Apply to invoke the settings.

136