Read/write image data
Read and write local QW0 outputs/outputs of the stations QW1 to QW8
You can read and write the local outputs directly via
Telegram structure
Byte |
| Meaning | Value (hex), sent by | ||||
|
|
|
|
| Master |
| Slave |
0 |
| Toggle byte |
| J page 94 |
|
| |
1 |
| Command |
|
|
|
| |
|
|
| Read |
| 91 |
| – |
|
|
| Write |
| B1 |
| – |
|
| Response |
|
|
|
| |
|
|
| Read | – |
| C2 | |
|
|
| successful |
|
|
|
|
|
|
| Write successful |
| – |
| C1 |
|
|
| Command |
| – |
| C0 |
|
|
| rejected |
|
|
|
|
2 |
| Len |
| 02 |
| 02 | |
|
|
|
|
|
|
| |
3 |
| Type |
| 04 |
| 04 | |
4 |
| Index1 |
| 00/01 – 08 |
| 00/01 – 08 | |
|
|
|
|
|
|
| |
5 |
| Data 1 |
|
|
| ||
|
|
| Read operation |
|
|
| |
|
|
| 00 |
| J Table 46 | ||
|
|
|
|
|
|
|
|
|
|
| For write | J Table 47 |
| 00 | |
|
|
| operation |
|
|
|
|
6 – 8 |
| Data 2 – 4 |
| 00 |
| 00 | |
|
|
|
|
|
|
|
|
1)00 = Local output
01 – 08 = Outputs of network stations 1 – 8
MN05013001E | For more information visit: www.EatonElectrical.com | 107 |