Read/write function block data

Table 73: Operand overview

0

 

Operand

 

 

Value

 

Read

 

Write

Index

 

 

 

 

 

(hex)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

 

Bit IO

 

 

Table 74

 

×

 

 

01

 

Mode/Parameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

 

Upper setpoint

SH

 

In integer range from

 

×

 

c1

 

 

 

 

 

–2147483648 to

 

 

 

 

03

 

Lower setpoint

SL

 

 

×

 

c1

 

 

+2147483647

 

 

04

 

Preset actual value

SV

 

 

×

 

c1

 

 

 

 

 

05

 

Actual value in Run mode

QV

 

 

 

×

 

 

1) The value can only be written if it is assigned to a constant in the program.

 

 

 

 

J

The data for index 2 to 5 is transferred as a 32-bit value in Intel format (Data 1 – Low Byte to Data 4 – High Byte).

Table 74: Index 0 – Bit IO

 

 

Bit

7

6

5

4

3

2

1

0

FB input Data 1

 

 

EN1

SE2

RE3

FB output Data 3

 

ZE4

CY5

FB6

OF7

1)Counter enable

2)Transfer preset actual value on rising edge

3)Reset actual value to zero

4)Zero: Status 1 if the value of the function block output QV (the counter status) equals zero

5)Carry: Status 1 if the value range is exceeded

6)

Fall below: Status 1 if the actual value

lower setpoint

7)

Overflow: Status 1 if the actual value

lower setpoint

MN05013001E

For more information visit: www.EatonElectrical.com

139

Page 143
Image 143