Device Operation

Setting the PROFIBUS-DPEvery PROFIBUS-DP station requires an unambiguous

station addressaddress in the PROFIBUS-DP structure. There are two ways of setting the PROFIBUS-DP addresses on the EZ204-DP:

Using the integrated display and keypad on the EZ or EZD basic unit

Using EZSoft on the PC.

Address range: 001 to 126

Setting the address on the basic unit with a display

Requirements:

The basic unit (EZ700, EZ800 or EZD) and the EZ204-DP expansion unit must be fed with power.

The basic unit has been unlocked (no password activated).

The basic unit has a valid operating system version (J page 15).

The basic unit must be in STOP mode.

The EZ204-DP is not communicating with the PROFIBUS- DP master (Bus LED is off).