Read/write function block data
Operating hours counters: O1 – O4
Telegram structure
Byte |
| Meaning | Value (hex), sent by | ||||
|
|
|
|
| Master |
| Slave |
0 |
| Toggle byte |
| J page 44 |
|
| |
1 |
| Command: |
|
|
|
| |
|
|
| Read | 89 |
| – | |
|
|
|
|
|
|
|
|
|
|
| Write | 8D |
| – | |
|
|
|
|
|
|
| |
|
| Response: |
|
|
| ||
|
|
| Read successful |
| – |
| C2 |
|
|
| Write successful |
| – |
| C1 |
|
|
| Command rejected |
| – |
| C01 |
2 |
| Type | 92 |
| 92 | ||
3 |
| Instance2 |
| 00 – 03 |
| 00 – 03 | |
4 |
| Index |
| J Table 30 |
|
| |
5 – 8 |
| Data 1 – 4 |
| depending on index, J Table 31 | |||
|
|
|
|
|
|
|
|
1)Possible causes J page 91
2)EZ provides 4 operating hours counters O1 to O4. These can be addressed using the instance (0 – 3).
Table 30: Operand overview
Index | Operand |
|
|
| Read |
| Write | |
(hex) |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
00 |
| Parameters J Table 31 |
|
|
| × |
|
|
01 |
| Control byte J Table 32 |
|
|
| × |
|
|
02 |
| Actual value |
| S12 |
| × |
| c1 |
03 |
| Counter setpoint 2 |
| S22 |
| × |
| c1 |
1)The value can only be written if it is assigned to a constant in the program.
2)A
MN05013001E | For more information visit: www.EatonElectrical.com | 79 |