EZ800/EZD Control Commands

Reading and writing markers

Byte

 

Meaning

Value (hex), sent by

 

 

 

 

 

 

Master

 

Slave

0

 

Toggle byte

 

J page 94

 

1

 

Command

 

 

 

 

 

 

 

Read

91

 

 

 

 

 

 

 

 

 

 

 

 

Write

B1

 

 

 

 

 

 

 

 

 

 

Response

 

 

 

 

 

 

Read successful

 

 

C2

 

 

 

Write successful

 

 

C1

 

 

 

Command rejected

 

 

C0

2

 

Len

 

J Table 51

 

J Table 51

 

 

 

 

 

 

 

3

 

Type

 

 

 

 

 

 

 

 

 

 

4

 

Index

 

 

 

 

5 – 8

 

Data 1 – 4

 

 

 

 

 

 

 

Read operation

00

 

J “Example 1”

 

 

 

 

 

 

 

on Page 118

 

 

 

For write operation

 

J “Example 2”

 

00

 

 

 

 

 

on Page 119

 

 

 

 

 

 

 

 

 

 

Table 51:

Byte 2 – 4: Len, Type, Index

 

 

 

 

 

 

 

 

 

 

 

 

 

Operand

 

 

 

 

Len

 

Type

 

Index

 

 

 

 

 

 

 

 

 

 

 

Marker bit

M1

..

M96

01hex

 

0Bhex

 

01 to 60hex

 

 

 

 

 

 

 

 

 

 

 

Marker byte

 

MB1

..

MB96

 

01hex

 

0Chex

 

01 to 60hex

Marker word

 

MW1

..

MW96

 

02hex

 

0Dhex

 

01 to 60hex

Marker double word

 

MD1

..

MD96

 

04hex

 

0Ehex

 

01 to 60hex

 

 

 

 

 

 

 

 

 

 

 

If required, refer to the more detailed description of the marker allocation in the EZ800 manual and EZD manual. Only a small extract of this manual is shown at this point in order to illustrate the allocation principle.