Read/write image data
The latest editions of these manuals are available as PDF files from the Internet at: www.EatonElectrical.com. EZ800 manual search term: MN05013004E. EZD manual search term:
MN05013005E.
Attention!
The function blocks and DW markers
EZ800/EZD operate with signed values.
Applies to | Left = Most |
|
|
|
|
| Right = Least | |
MD, MW, | significant bit, byte, |
|
|
|
|
| significant bit, byte, | |
MB, M | word |
|
|
|
|
| word | |
|
|
|
|
|
|
|
|
|
32 bit |
| MD1 |
|
|
|
|
|
|
16 bit |
| MW2 |
|
|
| MW1 |
| |
8 bit |
| MB4 |
| MB3 |
| MB2 |
| MB1 |
1 bit |
| M32 to M25 |
| M24 to M17 |
| M16 to M9 |
| M8 to M1 |
32 bit |
| MD2 |
|
|
|
|
|
|
16 bit |
| MW4 |
|
|
| MW3 |
| |
8 bit |
| MB8 |
| MB7 |
| MB6 |
| MB5 |
1 bit |
| M64 to M57 |
| M56 to M49 |
| M48 to M41 |
| M40 to M33 |
|
|
|
|
|
|
|
|
|
J
The relevant marker values are transferred in Intel format. In other words, the first byte is the low byte (Byte 5) and the last byte the high byte.
MN05013001E | For more information visit: www.EatonElectrical.com | 117 |