EZ800/EZD Control Commands

J

Reading local P buttons

The local P buttons are the display cursor buttons of the EZ800/EZD basic unit. You can scan the buttons in both Run and Stop mode.

Ensure that the P buttons are also activated via the SYSTEM menu (in the basic unit).

Only one byte has to be transferred for the P buttons.

Byte

 

Meaning

Value (hex), sent by

 

 

 

 

 

 

 

 

 

 

 

 

 

Master

 

Slave

0

 

Toggle byte

J page 94

 

 

 

 

 

 

 

 

 

 

1

 

Command: Read

 

91

 

 

 

Response:

 

 

 

 

 

 

 

Read successful

 

 

C2

 

 

 

Command

 

 

C0

 

 

 

rejected

 

 

 

 

2

 

Len

 

02

 

02

3

 

Type

 

06

 

06

4

 

Index

 

00

 

00

5

 

Data 1 (Low Byte)

 

00

 

J Table 48

6 – 8

 

Data 2 – 4

 

00

 

00

 

 

 

 

 

 

 

 

110

For more information visit: www.EatonElectrical.com