For more information visit: www.EatonElectrical.com
EZ800/EZD Control Commands
MN05013001E128
Block transfer function blocks BT01 .. BT32
Telegram structure
Table 61: Operand overview
Byte Meaning Value (hex), sent by
Master Slave
0 Toggle byte Jpage94 Jpage94
1 Command:
Read 92
Write B2
Response:
Read successful C2
Write successful C1
Command rejected C0
2Type 26 26
3 Instance 01 – 20 01 – 20
4 Index JTable61 JTable61
5 – 8 Data 1 – 4
Read operation 00 depending on index,
JTable62, 63
Write operation depending on index,
JTable62, 63 00
Index
(hex) Operand Read Write
00 Bit IO, JTable62 ×
01 Mode, JTable63 ×
02 Source range 1 I1 ×c1
03 Target range 2 I2 ×c1
04 Number of elements to compare: max. 192
bytes NO ×c1
1) The value can only be written if it is assigned to a constant in the program.