Ethernet Port Configuration Screen

Table 5-3 Ethernet Port Configuration Screen Field Descriptions (Continued)

Use this field…

To…

 

 

Full Duplex Flow

Set the flow control feature on each port for a specific mode. The

Control

choices are as follows:

(Selectable)

Symmetric – the port operates in Symmetric mode, causing the port to

 

 

interpret received PAUSE frames and allow the port to transmit PAUSE

 

frames when necessary at any speed connection.

 

Asymmetric Rx – the port operates in Asymmetric Rx mode, causing

 

the port to interpret received PAUSE frames and prevent the port from

 

transmitting PAUSE frames. This option is for Gigabit only.

 

Asymmetric Tx – the port operates in Asymmetric Tx mode, causing

 

the port to ignore PAUSE frames and allow the port to transmit PAUSE

 

frames when necessary. This option is for Gigabit only.

 

Disabled – full duplex flow control is off, causing the port to ignore

 

received PAUSE frames and prevent the port from transmitting PAUSE

 

frames at any speed connection.

 

Auto-Negotiate – when supported, the maximum flow control

 

capabilities of the port are reflected in the PAUSE bits of the

 

Auto-Negotiation registers. The ports’ flow control operational state is

 

determined by the results of Auto-Negotiation. This option is not

 

displayed if Auto-Negotiation is not supported on this port.

 

To change the settings for full duplex flow control, refer to

 

Section 5.3.1.

 

 

Half Duplex Flow

Set the Half Duplex flow control mode. Back pressure half duplex flow

Control

control is enabled when the port is set On, and disabled when the port

(Toggle)

is set Off. To change the settings, refer to Section 5.3.1.

 

 

SAVE TO ALL

Apply the currently displayed settings on the screen to all ports. To

PORTS

save the settings to all ports, highlight this command and press

(Command)

ENTER.

 

 

Port Configuration Menu Screens 5-11

Page 139
Image 139
Enterasys Networks 2H258, 2E253, 2H253, 2H252 manual Full Duplex Flow, Control, Half Duplex Flow, Save to ALL, Ports