VLAN Redirect Configuration Screen

Field Descriptions

Refer to Table 5-6for a functional description of each screen field.

Table 5-6 VLAN Redirect Configuration Screen Field Descriptions

Use this field…

To…

 

 

Source VLAN

See the VLAN ID of the VLANs that are currently set as source

(Read-Only)

VLANs.

 

 

Destination Port

See which ports are currently set as destination ports. (Multiple

(Read-Only)

VLANs may be assigned to a destination port.)

 

 

Frame Format

See the current frame format setting: RECEIVED, TAGGED, or

(Read-Only)

UNTAGGED. The default is RECEIVED.

 

RECEIVED – Frames are redirected in the format that they were

 

received by the switch device.

 

TAGGED – Frames are transmitted on the destination port with a

 

VLAN tag inserted according to the frame classification of the

 

receiving port.

 

UNTAGGED – Frames are transmitted on the destination port

 

without a VLAN tag regardless of the format of the received frame.

 

 

Redirect Errors

Unsupported.

 

 

Source VLAN [n]

Enter the VLAN ID of the VLAN that is to be changed to a source

(Modifiable)

VLAN. For details, refer to Section 5.7.1.

Destination Port [n] Select the port number that is to be changed to a destination port. For

(Selectable)

details, refer to Section 5.7.1.

 

 

Frame Format

Select the frame format for the transmission of redirected frames on the

(Selectable)

destination port. RECEIVED, TAGGED, or UNTAGGED may be

 

selected. Refer to the previously described read-only Frame Format

 

field for details about each format. The default setting is RECEIVED.

 

 

Redirect Errors

Unsupported.

 

 

Status

Add or delete source and destination ports selected in the Source

(Toggle)

VLAN [n] and Destination Port [n] fields.

 

 

Port Configuration Menu Screens 5-21

Page 149
Image 149
Enterasys Networks 2H253, 2E253, 2H252, 2H258 manual Source Vlan n