Built-in Commands

stpLegacyPathCost

Description: Enables or disables the use of 802.1D or 802.1t Path Cost bridging values on the device. The default is legacy 802.1D standard Path Cost values.

NOTE: When connecting ports between devices, it is recommended that the devices are all set to run either 802.1D or 802.1t. The path costs must be consistent between bridge ports of all the devices.

Table 11-2shows the path cost values when running 802.1t bridging.

Table 11-2 Path Cost Parameter Values

 

Link

Recommended

Recommended

Range

Speed

Value

Range

 

10 Mb/s

2,000,000*

200,000-

1-200,000,000

 

 

20,000,000

 

100 Mb/s

200,000*

20,000-

1-200,000,000

 

 

2,000,000

 

1 Gb/s

20,000

2,000- 200,000

1-200,000,000

10 Gb/s

2,000

200-20,000

1-200,000,000

*Bridges conforming to IEEE Std 802.1D, 1998 Edition, i.e., that support only 16-bit values for Path Cost, must use 65,535 as the Path Cost for these link speeds when used in conjunction with Bridges that support IEEE Std 802.1t (32 bit) Path Cost values.

Syntax: stpLegacyPathCost [ enable disable status]

Options: enable – Enables the device to use spanning tree legacy 802.1D Path Cost values.

disable – Returns the device to the default setting of using the spanning tree 802.1t Path Cost values.

status – Displays the current status of the Path Cost setting (enabled or disabled).

11-32Network Tools Screens

Page 324
Image 324
Enterasys Networks 2E253, 2H253 manual StpLegacyPathCost, Recommended, Value, Syntax stpLegacyPathCost enable disable status