EAP Statistics Menu Screen

Table 3-12 EAP Authenticator Statistics Screen Field Descriptions (Continued)

Use this field…

To…

 

 

Response Id Frames

See counts of EAP response identification type frames received by the

Rx

authenticator.

(Read-Only)

 

 

 

Response Frames

See counts of EAP response type frames received by the authenticator.

Rx

 

(Read-Only)

 

 

 

Request Id Frames

See counts of EAP request identification type frames transmitted by the

Tx

authenticator.

(Read-Only)

 

 

 

Request Frames Tx

See counts of EAP request identification type frames transmitted by the

(Read-Only)

authenticator.

 

 

Invalid Frames Rx

See counts of frames received by the authenticator that have an

(Read-Only)

unrecognizable frame type.

 

 

Length Error

See counts of frames received by the authenticator with an invalid

Frames Rx

length field for the frame body,

(Read-Only)

 

 

 

Frame Version

See the EAP protocol version present in the most recent EAP frame.

(Read-Only)

 

 

 

Frame Source

See the source MAC address for the most recent EAP frame received.

(Read-Only)

 

 

 

Port Number

Select the port number to display the associated EAP Authenticator

(Selectable)

Statistics. To select a port number, use the arrow keys to highlight the

 

Port Number field. Then step to the correct port number using the

 

SPACE bar and press ENTER to display the associated port EAP

 

Authenticator Statistics.

CLEAR COUNTERS

(Command)

Set the octets and frame counters to zero for a particular port. To clear the counters, highlight CLEAR COUNTERS and press ENTER.

NOTE: This command clears the counters for this LM screen, but it does not clear the associated MIB objects.