117
CHAPTER 5 TIME-BASE TIMER
Note:
Because oscillation cycles vary immediately after oscillation starts, the oscillation stabilization wait
time is listed for reference.
Watchdog timer 222/FCH (Approximately 335.5 ms) Watchdog timer count up clock
A/D converter 28/FCH (Approximately 20.5 ยตs) Continuous activation clock
FCH: Oscillation frequency
The values enclosed in parentheses are time intervals when the oscillation frequency is 12.5 MHz.
Table 5.1-2 Clock Cycles Supplied by Time-base Timer (2/2)
Clock supplied to Clock cycle Remarks