CHAPTER 12 A/D CONVERTER
Notes on interrupt requests
If A/D conversion is reactivated (ADC1: AD = 1) and terminated at the same time, the interrupt request
flag bit (ADC1: ADI) is not set.
Conversion time
Changing the oscillation frequency or clock speed (gear functions) affects the conversion speed of A/D
conversion functions.
Input clock of continuous activation
The output of an 8/16-bit capture timer/counter is affected by gear functions. The output of a time-base
timer is not affected by gear functions. Clearing a time-base timer affects cycles.
Since the output of an 8/16-bit capture timer/counter is the output of the 16-bit mode, the 8-bit mode cannot
be used.