208
CHAPTER 9 12-BIT PPG TIMER
91 to 9
18 tINST 36 tINST 144 tINST 2304 tINST 1/9 11.1%
10 1 to 10 20 tINST 40 tINST 160 tINST 2560 tINST 1/10 10.0%
::: :
20 1 to 20 40 tINST 80 tINST 320 tINST 5120 tINST 1/20 5.0%
::: :
100 1 to 100 200 tINST 400 tINST 1600 tINST 25600 tINST 1/100 1.0%
::: :
500 1 to 500 1000 tINST 2000 tINST 8000 tINST 128000 tINST 1/500 0.2%
::: :
1000 1 to 1000 2000 tINST 4000 tINST 16000 tINST 256000 tINST 1/1000 0.1%
::: :
2000 1 to 2000 4000 tINST 8000 tINST 32000 tINST 512000 tINST 1/2000 0.05%
::: :
3000 1 to 3000 6000 tINST 12000 tINST 48000 tINST 768000 tINST 1/3000 0.03%
::: :
4095 1 to 4095 8190 tINST 16380 tINST 65520 tINST 1048320 tINST 1/4095 0.02%
tINST: Instruction cycle
Table 9.1-2 Resolutions and Output Pulse Cycle Periods Supported when the Timer is Used as a 12-bit PPG (2/2)
Compare
value for
cycle
period
Range of
available
compare
values for
"H" width
Output pulse cycle period
Resolution Minimum-
step duty
cycle
Count clock
= 2 tINST
Count clock
= 4 tINST
Count clock
= 16 tINST
Count clock
= 256 tINST