3.Refer to the upper right hand corner of the screen for Handshaking line status. RTS, CTS, DSR, and DTR should all be HIGH. The DCD line is not looked at by the terminal emulation program therefore its status can be ignored. If these signals are not high at this point, check to ensure the correct cable is connected.

4.Ensure that all red LEDs on the front of the Model 24SII DES are off (all ports off-line), and that the green 'power on' LED is illuminated.

You may now configure the Model 24SII DES from the PC keyboard.

NOTE: Keyboard entries must be CAPITAL LETTERS. Put your keyboard in the CAPS LOCK mode.

5.Depress function key: F1 followed by the module number that you wish to configure (1 to 6).

NOTE: The F1 key in TERM sends the character sequence Control-T(14 Hex) followed by the ASCII capital C character (43 Hex).

The main configuration menu for the selected module will appear. From this point on, configuration of the Model 24SII DES will be accomplished by following the plain-English menus that will prompt you. Enter the letter corresponding to the desired operation. Refer to the chart provided on the following page for assistance.

NOTE: Once F1 and the desired module number are sent, the LEDs for Port 1 and the ports for the selected module on the front of the Model 24SII DES will illuminate and will remain illuminated while you are in configuration mode. If only two LEDs illuminate, if no LEDs illuminate, or if no menus appear, this indicates that an incorrect character sequence has been received. If this occurs, wait for all red LEDs to go out and re-send F1 followed by the desired module number (1 to 6).

￿￿