If you are connecting an EIA-232 device to the M24SII-V07 module using 8-wire Operation, please see Appendix A.5 for device adapter pinouts and recommended cabling.

When connecting an EIA-422 device to the M24SII-V07 module using 8-wire Operation, the cable required to connect the two devices must have TX+ wired to RX+ (and vice versa), TX- wired to RX- (and vice versa), HSO wired to HSI (and vice versa), and have the signal grounds connected. Please Figure 9.

M24SII-V07 (EIA-422, 8-wire)

Equipment

RJ-45

Connections

1

HSO

HSI

 

2

GND

GND

 

3

TX+

RX+

 

4

TX-

RX-

 

5

RX-

TX-

 

6

RX+

TX+

 

7

GND

GND

 

8

HSI

HSO

 

Figure 9: M24SII-V07 EIA-422 (8-wire) Connection

If you are connecting an EIA-422 device other than another BayTech product, you must refer to the operator's manual for your equipment to determine which pins are defined as TX+, TX-, RX+, RX-, HSI, HSO, and signal ground (common).

If you are connecting another BayTech product (such as Tran-x) using EIA-422 protocol and 8-wire Operation, please refer to Appendix A.7.1 for the recommended cable pinout.

￿￿