CAUTION: If you have a M24SII-V07 installed as Module 1, do not configure Port 1 of this module for any baud rate higher than 115,200 or you will locked out of configuration mode and unable to program the various features of the Model 24SII.

The Model 24SII DES will respond with:

Enter Request

:6

Bidirectional

 

---------------------------------------------------

Port

Baud

Word

Stop

Parity

Xon

/

Xoff

Rate

Size

Bits

Xmit

Recv

---------------------------------------------------

1

9600

8

1

None

Off Off

2

9600

8

1

None

Off Off

3

9600

8

1

None

Off Off

4

9600

8

1

None

Off Off

--------------------------------------------------

 

Enter

Port Number (ENTER=Exit) :

 

 

 

You should enter the number of the port that you wish to reconfigure, and then strike the Enter key. For example, if you sent "2" and Enter, the Model 24SII DES will respond with the current status of Port 2 and a menu of the available options:

Bidirectional

---------------------------------------------------

Port

Baud

Word

Stop

Parity

Xon

/

Xoff

Rate

Size

Bits

Xmit

Recv

---------------------------------------------------

2 9600 8 1 None Off Off

--------------------------------------------------

Exit/Save......1

Set Stop Bits.....

4

Set

Baud

Rate..2

Set

Parity........

5

Set

Word

Size..3

Set

XON/XOFF......

6

Enter Request :

You may now reconfigure Port 2 by selecting the appropriate option (1-6) from the menu.

NOTE: The M24SII-V07 module will also show Set 4-Wire/8-Wireas item number 7.

￿￿