Enter the module number of the desired printer. For example, if the desired printer is connected to Module 6, enter "6" in response to the prompt.

The Model 24SII DES will respond with:

Default Port is

2

Enter New Value

(1 to 4), or ENTER for no change :

Enter the port number of Module 6 that the desired printer is connected to. For example, if the desired printer is connected to Port 1 of Module 6, enter "1" in response to the prompt. The Model 24SII DES will respond with:

--------------------------------------------------

Port

Logical Name

Port

Port

Prnt

 

Type

Desig

Assn

--------------------------------------------------

1

Device A

Serial Computer

0

2

Device B

Serial Printer

1-2

3

Device

C

Serial

Computer

6-1

4

Device

D

Serial

Computer

0

--------------------------------------------------

Enter Port Number (ENTER=Exit) :

You may now reconfigure another computer port, or exit by striking the Enter key. The Model 24SII DES will save the new Default Printer Assignment(s) permanently in non-volatile memory and subsequently power-up with the new assignment(s) in effect.

The Model 24SII DES will now return to the main configuration menu (see Section 8.1).

￿￿