OPTION ACCESSIBILITY: Through Port 1 of Module 1 only.

By responding to the Enter Request: message at the end of the main configuration menu (see Section 8.1) with "4" (Program Port Select Code), you may change the Port Select Code to a user-defined code. This Port Select Code consists of any ASCII character string (1 to 8 characters).

The Model 24SII DES will respond with the following:

Enter Request :4

Port Select Code is: $SELECT

Enter Port Select Code (Max. 8 characters) or ENTER for no change :

Enter the new Port Select Code. If less than 8 characters are entered, you must follow entry by striking the Enter key.

NOTE: Non-printable characters are acceptable, but they will not appear in the Status menu.

For example, if you entered #PORT, the Model 24SII DES will respond with:

Port Select Code is: #PORT

Enter Port Select Code (Max. 8 characters) or ENTER for no change :

If no additional change is desired, strike the Enter key to exit.

The Model 24SII DES will save the new Port Select Code permanently in non-volatile memory and will subsequently power-up with that code in effect.

The Model 24SII DES will now return to the main configuration menu (see Section 8.1).

￿￿