NOTE: A serial computer connected to a port other than Port 1 of Module 1 cannot access configuration mode for its module while the master configuration port is configuring a module.

NOTE: If a computer attempts to configure a feature that is only accessible to the master configuration port, Port 1 of Module 1, the computer will be sent this message by the Model 24SII DES:

This Option is accessible via Port 1, Module 1 ONLY. Strike any Key to continue

NOTE: If a computer port other than the master configuration port attempts to access configuration mode of a module that it is not connected to, the Model 24SII DES will ignore the configuration request and create a print job consisting of Control-T, C, and the module number.

CAUTION: If you have a M24SII-V07 installed as Module 1, do not configure Port 1 of this module for any baud rate higher than 115,200 or you will locked out of configuration mode and unable to program the various features of the Model 24SII.

￿￿