Chapter 7 Power and Signal Distribution
7.2.1 POWER SUPPLY ASSEMBLY
The D315 models use a
Table
Table
220-Watt Power Supply Assembly Specifications
|
| Range/ | Min. Current | Max. | Surge | Max. |
|
|
| Tolerance | Loading [1] | Current | Current [2] | Ripple |
|
| Input Line Voltage: |
|
|
|
|
|
|
| 115VAC setting | 90 - 132 VAC |
| ||||
| 230VAC setting | 180 - 264 VAC |
|
|
|
|
|
| Line Frequency | 47 - 63 Hz |
| ||||
| Constant Input (AC) Current | 6.00 A |
| ||||
| +3.33 VDC Output | +/- 4% | 1.0 A | 15.0 A | 15.0 A | 50 mV |
|
| +5 VDC Output | +/- 5 % | 1.0 A | 11.0 A | 11.0 A | 50 mV |
|
| +5.05 AUX Output | +/- 4 % | 0.0 A | 3.00 A | 3.00 A | 50 mV |
|
| +12 VDC Output | +/- 5 % | 0.1 A | 5.00 A | 7.50 A | 120 mV |
|
| +12.8 VDC Output (Vcpu) | +/- 12 % | 0.0 A | 7.50 A | 7.50 A | 200 mV |
|
| +/- 10 % | 0.0 A | 0.15 A | 0.15 A | 200 mV |
|
NOTES:
[1]Minimum loading requirements must be met at all times to ensure normal operation and specification compliance.
[2]Surge duration no longer than 10 seconds with
The D325 models use a
Table
Table
|
|
| Range/ | Min. Current | Max. | Surge | Max. |
|
|
|
| Tolerance | Loading [1] | Current | Current [2] | Ripple | |
| Input Line Voltage: |
|
|
|
|
|
| |
| 115VAC setting | 90 - 132 VAC |
| |||||
| 230VAC setting | 180 - 264 VAC |
|
|
|
|
| |
| Line Frequency | 47 - 63 Hz |
| |||||
| Constant Input (AC) Current | 6.00 A |
| |||||
| +3.33 | VDC Output | +/- 3.3% | 1.0 A | 19.0 A | 19.0 A | 50 mV | |
| +5.08 | VDC Output | +/- 3.3 % | 1.0 A | 14.0 A | 14.0 A | 50 mV | |
| +5.08 | AUX Output | +/- 4 % | 0.0 A | 3.00 A | 3.00 A | 50 mV | |
| +12 VDC Output | +/- 5 % | 0.1 A | 5.00 A | 7.50 A | 120 mV | ||
| +12.8 | VDC Output (Vcpu) | +14/- 10 % | 0.0 A | 9.00 A | 9.00 A | 200 mV | |
| +/- 10 % | 0.0 A | 0.15 A | 0.15 A | 200 mV |
NOTES:
[1]Minimum loading requirements must be met at all times to ensure normal operation and specification compliance.
[2]Surge duration no longer than 10 seconds with
Second Edition - April 2003