HPMA User Guide

DICOM

DICOM is optional The configuration settings for the LDR X DICOM component allow

on the HPMA. you to set the active state of the protocol component, select whether or not to enable the protocol on service restarts, and reset transaction

counters to clear alarms.

The LDR advertises two ports to the grid, one for query and retrieve operations and one for ingest. When the DICOM component is in “Online” state, both ports are advertised. The “Online (Read-Only)” state advertises only the Q/R port and not the ingest port.

Table 66: LDR X DICOM Component Configuration Settings

Prompt

Type

Description

 

 

 

DICOM State

Pull-down

Sets the component to be either:

 

menu

Offline—No DICOM transactions are allowed,

 

 

 

and any entity that tries to establish a DICOM

 

 

 

association to the LDR receives an error message.

 

 

 

Active associations are completed normally.

 

 

 

DICOM component counter attributes are reset to

 

 

 

zero.

 

 

Redirect—Transparently redirects associations to

 

 

 

other LDR services. No DICOM processing is

 

 

 

performed locally.

 

 

Online (Read-Only)—Only the Q/R DICOM port

 

 

 

is advertised to the grid.

 

 

Online—Normal operation.

 

 

 

Auto-Start DICOM

Check box

Enables the DICOM component when the service is

 

 

restarted. If not selected, the DICOM component

 

 

remains Offline until explicitly enabled.

 

 

If the check box is selected, the state on restart

 

 

depends on the state of the Storage component. If the

 

 

storage component is read-only on startup, the

 

 

DICOM interface is also read-only. If the storage

 

 

component is online, then DICOM is also online.

 

 

Otherwise the DICOM interface remains in the

 

 

Offline state.

 

 

 

Reset DICOM

Check box

When selected and applied, the counter attributes for

Counts

 

DICOM transactions are reset to zero. This can be

 

 

used to clear alarms.

 

 

 

 