Services and Components
Table 15: CLB Service Attributes (cont.)
| Attribute | Type / Units | Description | C | T | Alarm | ||
| 
 | 
 | 
 | 
 | 
 | 
 | ||
| Service | Duration | Total duration the service has | 
 | 
 | N/A | ||
| Runtime | 
 | functioned since installation; the | 
 | 
 | 
 | ||
| 
 | 
 | sum of all uptimes. | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | ||
| Restarts | Count | Total number of restarts since | 
 | 
 | N/A | ||
| 
 | 
 | installation. | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | ||
| Reference | Text | Indicates the origin of timing | 
 | 
 | N/A | ||
| Clock Source | 
 | information; used for audit mes- | 
 | 
 | 
 | ||
| 
 | 
 | sages, communication, and timing | 
 | 
 | 
 | ||
| 
 | 
 | functions: | 
 | 
 | 
 | ||
| 
 | 
 | • | NTP | 
 | 
 | 
 | |
| 
 | 
 | • | GPS (not used in the HPMA) | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | ||
| Reference | Enumerated | Indicates the current condition of | 
 | 
 | TRFS | ||
| Clock Status | Text | the timing source: | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 0 | = Stable | 
 | 
 | 
 | 
| 
 | 
 | 
 | 1 | = Flywheeling | 
 | 
 | 
 | 
| 
 | 
 | 
 | 2 | = Unstable | 
 | 
 | 
 | 
| 
 | 
 | 
 | 3 | = Offline | 
 | 
 | 
 | 
| 
 | 
 | 
 | 4 | = Unknown | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | ||
| Local Clock | Enumerated | Indicates the condition of the | 
 | 
 | TRSS | ||
| Status | Text | internal timing system: | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 0 | = Calibrating | 
 | 
 | 
 | 
| 
 | 
 | 
 | 1 | = Synchronizing | 
 | 
 | 
 | 
| 
 | 
 | 
 | 2 | = Syntonizing | 
 | 
 | 
 | 
| 
 | 
 | 
 | 3 | = Flywheeling | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | (Recalibrating) | 
 | 
 | 
 | 
| 
 | 
 | 
 | 4 | = Flywheeling | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | ||
| Local Clock | ppm | The error between the local clock | 
 | 
 | N/A | ||
| Rate Error | 
 | and the reference clock. | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | ||
| Local Clock | ppm | The cumulative offsets (since last | 
 | 
 | N/A | ||
| Rate Drift | 
 | restart) required by the local clock | 
 | 
 | 
 | ||
| 
 | 
 | to keep in sync with the reference | 
 | 
 | 
 | ||
| 
 | 
 | clock. | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | ||
| Network | µs | Rough measure of how different | 
 | 
 | TNER | ||
| Neighbor | 
 | this service’s clock is from that of | 
 | 
 | 
 | ||
| Drift | 
 | the ADC services. | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
69
HP Medical Archive