600 Series
Audible Beeps: None
Possible Cause: Diskette controller circuitry failure occurred.
Action:
1.Be sure the diskette drive cables are connected.
2.Replace the diskette drive, the cable, or both.
3.Run Insight Diagnostics ("HP Insight Diagnostics" on page 61) and replace failed components as indicated.
Audible Beeps: None
Possible Cause: The boot sector on the boot disk is corrupt.
Action:
1.Remove the diskette from the diskette drive.
2.Replace the diskette in the drive.
3.Reformat the diskette.
Audible Beeps: 2 short
Possible Cause: Mismatch in drive type occurred.
Action: Run the server setup utility to set the diskette drive type correctly.
Audible Beeps: 2 short
Possible Cause: A hardware conflict in the system is preventing the diskette drive from operating properly.
Action:
1.Run the server setup utility to configure the diskette drive port address and manually resolve the conflict.
2.Run Insight Diagnostics ("HP Insight Diagnostics" on page 61) and replace failed components as indicated.
Audible Beeps: 2 short
Possible Cause: A hardware conflict in the system is preventing the diskette drive from operating properly.
Action:
1.Run the server setup utility to configure the diskette drive port address and manually resolve the conflict.
Error messages 108