Description: The number of cache lines experiencing excessive ECC errors has reached a preset limit. Therefore, the cache has been shut down.
Action:
1.Reseat the cache to the controller.
2.If the problem persists, replace the cache.
Accelerator Status: Obsolete Data Detected
Description: During reset initialization, obsolete data was found in the cache due to the drives being moved and written to by another controller.
Action: No action is required. The controller either writes the data to the drives or discards the data completely.
Accelerator Status: Obsolete Data was Discarded
Description: During reset initialization, obsolete data was found in the cache, and was discarded (not written to the drives).
Action: No action is required.
Accelerator Status: Obsolete Data was Flushed (Written) to Drives
Description: During reset initialization, obsolete data was found in the cache. The obsolete data was written to the drives, but newer data may have been overwritten.
Action: If newer data was overwritten, you may need to restore newer data; otherwise, normal operation should continue.
Accelerator Status: Permanently Disabled
Description: Array accelerator board has been permanently disabled. It will remain disabled until it is reinitialized using ACU.
Action: Check the Disable Code field. Run ACU ("Array Configuration Utility" on page 54) to reinitialize the array accelerator board.
Accelerator Status: Possible Data Loss in Cache
Description: Possible data loss was detected during
Action: No way exists to determine if dirty or bad data was in the cache and is now lost.
Accelerator Status: Temporarily Disabled
Description: Array accelerator board has been temporarily disabled.
Action: Check the Disable Code field.
Accelerator Status: Unrecognized Status
Description: A status was returned from the array accelerator board that ADU does not recognize.
Action: Obtain the latest version of ADU ("Array Diagnostic Utility" on page 63).
Error messages 75