Drive Monitoring Features Are Unobtainable
Description: ADU ("Array Diagnostic Utility" on page 63) is unable to get monitor and performance data due to a fatal command problem (such as drive
Action: Check for other errors such as
Drive Monitoring is NOT Enabled for SCSI Port X Drive ID Y
Description: The monitor and performance features have not been enabled on this drive.
Action: Run the server setup utility to initialize the monitor and performance features.
Drive
Description: ADU issued a command to a physical drive and the command was never acknowledged.
Action: The drive or cable may be bad. Check the other error messages on the Diagnostics screen to determine resolution.
Drive X Indicates Position Y
Description: Message indicates a designated physical drive, which seems to be scrambled or in a drive bay other than the one for which it was originally configured.
Action:
1.Examine the graphical drive representation on ADU ("Array Diagnostic Utility" on page 63) to determine proper drive locations.
2.Power down the server.
3.Remove drive X and place it in drive position Y.
4.Rearrange the drives according to the ADU instructions.
Duplicate Write Memory Error
Description: Data cannot be written to the array accelerator board in duplicate due to the detection of parity errors. This is not a
Action: Replace the array accelerator board.
Error Occurred Reading RIS Copy from SCSI Port X Drive ID
Description: An error occurred while ADU ("Array Diagnostic Utility" on page 63) was trying to read the RIS from this drive.
Action: HP stores the hard drive configuration information in the RIS. If multiple errors occur, the drive may need to be replaced.
FYI: Drive (Bay) X is
Description:
Action: If problems exist with this drive, replace it with a supported drive.
Error messages 80