WARNING: Storage Enclosure on SCSI Bus X Indicated it is Operating in Single
Ended Mode...
...SOLUTION: This usually occurs when a
Description: One or more
Action: The array continues to operate, but installing all LVD drives maximizes performance.
Write Memory Error
Description: Data cannot be written to the cache memory. This typically means that a parity error was detected while writing data to the cache. This can be caused by an incomplete connection between the cache and the controller. This is not a data loss circumstance.
Action: Power down the system and be sure that the cache board is fully connected to the controller.
Wrong Accelerator
Description: This may mean that the board was replaced in the wrong slot or was placed in a system previously configured with another board type. Included with this message is a message indicating (1) the type of adapter sensed by ADU ("Array Diagnostic Utility" on page 63), and (2) the type of adapter last configured in EISA NVRAM.
Action: Check the diagnosis screen for other error messages. Run the server setup utility to update the system configuration.
POST error messages and beep codes
Introduction to POST error messages
The error messages and codes in this section include all messages generated by ProLiant servers. Some messages are informational only and do not indicate any error. A server generates only the codes that are applicable to its configuration and options.
HP ProLiant
IMPORTANT: This guide provides information for multiple servers. Some information may not apply to the server you are troubleshooting. Refer to the server documentation for information on procedures, hardware options, software tools, and operating systems supported by the server.
WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components.
Error messages 92