1611-Fan x Not Present (Fan Zone I/O)

Audible Beeps: 2 short

Possible Cause: Required fan is not installed or spinning.

Action:

1.Check the fans to be sure they are working.

2.Be sure each fan cable is properly connected, if applicable, and each fan is properly seated.

3.If the problem persists, replace the failed fans.

1611- Power Supply Zone Fan Assembly Failure Detected. Either...

...the Assembly is not installed or multiple fans have failed. Audible Beeps: None

Possible Cause: Required fans are missing or not spinning.

Action:

1.Check the fans to be sure they are installed and working.

2.Be sure the assembly is properly connected and each fan is properly seated.

3.If the problem persists, replace the failed fans.

4.If a known working replacement fan is not spinning, replace the assembly.

1611-Power Supply Zone Fan Assembly Failure Detected. Single fan...

...failure. Assembly will provide adequate cooling.

Audible Beeps: None

Possible Cause: Required fan is not spinning.

Action: Replace the failed fan to provide redundancy, if applicable.

1611-Primary Fan Failure (Fan Zone System)

Audible Beeps: None

Possible Cause: A required fan is not spinning.

Action: Replace the failed fan.

1611-Redundant Fan Failure (Fan Zone System)

Audible Beeps: None

Possible Cause: A redundant fan is not spinning.

Action: Replace the failed fan.

1612-Primary Power Supply Failure

Audible Beeps: 2 short

Possible Cause: Primary power supply has failed.

Action: Replace power supply.

Error messages 111