1774-Slot X Drive Array - Obsolete Data Found in Array Accelerator

Audible Beeps: None

Possible Cause: Drives were used on another controller and reconnected to the original controller while data was in the original controller cache. Data found in the array accelerator is older than data found on the drives and has been automatically discarded.

Action: Check the file system to determine whether any data has been lost.

1775-Slot X Drive Array - ProLiant Storage System Not Responding SCSI Port Y:

...Check storage system power switch and cables. Turn the system power off while checking the ProLiant power and cable connections, then turn the system power back on to retry.

Audible Beeps: None

Possible Cause: Storage system problem detected. A SCSI enclosure seems to be connected to the specified SCSI bus, but no drives or SCSI backplane processor were detected on this bus.

Action:

1.Power down the server.

2.Check the external ProLiant power switch. External drives must all be powered up before the main system is.

3.Be sure the cables are connected properly and securely.

4.Update the storage device to the latest firmware version ("Firmware maintenance" on page 65).

5.If the problem persists, replace the cable, backplane, or Smart Array Controller.

1775-Slot X Drive Array - ProLiant Storage System Not Responding SCSI Port Y:

...Turn system and storage box power OFF and check cables. Drives in this box and connections beyond it will not be available until the cables are attached correctly.

Audible Beeps: None

Action: For cabling configuration information, refer to the storage enclosure documentation.

1776-Slot X Drive Array - SCSI Bus Termination Error

...Internal and external drives cannot both be attached to the same SCSI port. SCSI port Y: Check cables

Audible Beeps: None

Possible Cause: External and internal connectors of the specified SCSI ports are connected to drives. The indicated SCSI bus is disabled until this problem is resolved.

Action: The SCSI bus is not properly terminated when internal and external drives are connected concurrently to the same SCSI bus.

1.Power down the server.

2.Be sure the cables to the specified port are connected properly and securely ("Loose connections" on page 15).

3.Reconfigure the drives to different SCSI ports.

1776-Slot X Drive Array - Shared SAS Port Connection Conflict Detected - Ports 1I, 1E: Storage connections detected on both shared internal and external ports.

...Controller selects internal port until connection is removed from one of the ports.

Audible Beeps: None

Action: For cable configuration information, refer to the controller documentation.

Error messages 117

Page 117
Image 117
HP ProLight Server manual Slot X Drive Array Obsolete Data Found in Array Accelerator

ProLight Server specifications

The HP ProLiant server series is designed to deliver exceptional performance, scalability, and reliability for a variety of workloads, making it a popular choice among businesses of all sizes. Known for its robust architecture, the ProLiant series integrates cutting-edge technologies to support critical applications, virtualization, and cloud computing.

One of the defining features of HP ProLiant servers is their advanced management capabilities, facilitated by HP Integrated Lights-Out (iLO) technology. This embedded management tool offers remote access and monitoring capabilities, enabling IT administrators to oversee servers even when they are powered down. iLO provides essential features like firmware lifecycle management, power consumption monitoring, and system health checks, all of which simplify management and enhance uptime.

HP ProLiant servers leverage Intel's latest Xeon processors, which deliver impressive processing power and energy efficiency. The architecture supports multi-core processing, allowing for greater parallelism and improved operational efficiency. Furthermore, the series supports various memory configurations, with options for scalable and high-speed memory that can significantly enhance performance in memory-intensive applications.

Storage is another strength of the HP ProLiant series. The servers provide a range of storage options, including HDDs and SSDs, which enable organizations to configure systems to meet their performance and capacity requirements. HP’s Smart Array technology allows for advanced RAID capabilities, providing added data protection and redundancy, ensuring that critical information remains secure even during hardware failures.

HP ProLiant servers also focus on security, featuring built-in security technologies to protect against potential threats. Technologies such as silicon root of trust, secure boot, and firmware validation help safeguard server integrity from the ground up.

Scalability is essential for growing businesses, and the ProLiant series is designed to accommodate increasing workloads efficiently. Its modular architecture allows for seamless upgrades, ensuring that organizations can expand their infrastructure as needed without extensive downtime or resource expenditure.

In conclusion, the HP ProLiant server series blends performance, management, security, and scalability, making it a reliable choice for enterprise IT environments. With its robust features, advanced technologies, and focus on security and manageability, HP ProLiant servers provide businesses with the capability to meet their evolving IT demands effectively.