Audible Beeps: None

Possible Cause: One or more logical drives failed due to loss of data in posted-writes memory.

Action:

Press the F1 key to continue with the logical drives disabled.

Press the F2 key to accept data loss and re-enable logical drives. After pressing the F2 key, check integrity of the file system and restore lost data from backup.

Event list error messages

Introduction to event list error messages

This section contains event list error messages recorded in the IML, which can be viewed through different tools.

The format of the list is different when viewed through different tools. An example of the format of an event as displayed on the IMD follows:

**001 of 010**

---caution---

03/19/2002 12:54 PM FAN INSERTED Main System Location: System Board Fan ID: 03 **END OF EVENT**

WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components.

IMPORTANT: This guide provides information for multiple servers. Some information may not apply to the server you are troubleshooting. Refer to the server documentation for information on procedures, hardware options, software tools, and operating systems supported by the server.

NOTE: The error messages in this section may be worded slightly different than as displayed by the server.

A CPU Power Module (System Board, Socket X)...

...A CPU Power Module (Slot X, Socket Y) Failed

Event Type: Power module failure

Action: Replace the power module. In the case of an embedded power module, replace the system board.

ASR Lockup Detected: Cause

Event Type: System lockup

Action: Examine the IML to determine the cause of the lockup, and then refer to the HP ROM-Based Setup Utility User Guide, on the server Documentation CD or at the SmartStart website (http://www.hp.com/servers/smartstart), for more information.

Error messages 124