Critical Error Occurred Prior to this Power-Up

Audible Beeps: None

Possible Cause: A catastrophic system error, which caused the server to crash, has been logged.

Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 61) and replace failed components as indicated.

Fan Solution Not Fully Redundant

Audible Beeps:

Possible Cause: The minimum number of required fans is installed, but some redundant fans are missing or failed.

Action: Install fans or replace failed fans to complete redundancy.

Fan Solution Not Sufficient

Audible Beeps:

Possible Cause: The minimum number of required fans is missing or failed.

Action: Install fans or replace any failed fans.

Fatal DMA Error

Audible Beeps: None

Possible Cause: The DMA controller has experienced a critical error that has caused an NMI.

Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 61) and replace failed components as indicated.

Fatal Express Port Error

Audible Beeps: None

Possible Cause: A PCI Express port has experienced a fatal error that caused an NMI.

Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 61) and replace the failed PCI Express boards or reseat loose PCI Express boards.

Fatal Front Side Bus Error

Audible Beeps: None

Possible Cause: The processor front-side bus experienced a fatal error.

Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 61) and replace any failed processors or reseat any loose processors.

Fatal Global Protocol Error

Audible Beeps: None

Possible Cause: The system experienced a critical error that caused an NMI.

Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 61) and replace failed components as indicated.