Related Commands: “show power-supply” (page 171) “show sensor” (page 172)

show host

Synopsis: The show host command displays the Domain Name System configuration of the chassis.

Syntax: show host

Command Modes: User-execute and privileged-execute modes.

Privilege Level: Fibre Channel read-only user.

Usage Guidelines: The information displayed is the network domain of the chassis, and the DNS servers that are used to resolve network names to IP addresses.

Examples:

HP-IB# show host

============================================================================

Host Information

============================================================================

name-server-one : 10.3.106.20

name-server-two : 0.0.0.0 domain-name : shastaHP-IB#

Defaults: This command has no defaults.

Related Commands: “hostname” (page 200)

show ib

The show ib command displays information about the subnet manager running on the InfiniBand fabric. The information displayed is used to configure the subnet manager, including the nodes and ports within that subnet.

Synopsis: The show ib sm configuration command displays information about the subnet managers running on the InfiniBand fabric.

Syntax: show ib sm configuration

This command requires several keywords, which are shown in the table below.

Table B-9 show ib Keyword Descriptions

Keyword

Description

configuration

Displays the configuration of the subnet manager that is running on the InfiniBand fabric. It includes

 

information like the subnet manager GUID, SM Key, and status. See “show ib sm configuration”

 

on page 170.

neighbor

Displays the inter-connectivity of nodes on the subnet and their GUIDs. It identifies the GUID of

 

each node, the node ports, and the ports to which they are linked. It includes information like node

 

type and status. See “show ib sm neighbor” on page 172.

node

Displays the configuration and attributes of nodes on the subnet. In addition to node and port

 

GUIDs, this command keyword identifies the node device and vendor. See “show ib sm node” on

 

page 174.

port

Displays the configuration and attributes of ports on the subnet. It includes information like link

 

and virtual lane attributes, as well as packet violations. See “show ib sm port” on page 177.

switch

Displays the configuration and capabilities of switches on the subnet. This includes information

 

like the type of forwarding supported and switch capabilities. See “show ib sm switch” on page

 

184.

show ib sm configuration

Synopsis: The show ib sm configuration command displays information about the subnet managers running on the InfiniBand fabric.

Show Commands 141

Page 141
Image 141
HP UX 11i v2 Networking Software manual Show host, Show ib sm configuration, Table B-9 show ib Keyword Descriptions